Products

A full range of alkaline electrolysers as well as pressurised and gas treatment equipment.

Integrated unit for producing and drying hydrogen

Release Date:2023-03-20 14:21:46

product details

1.The parts of the plant:main equipment, auxiliary equipment and electric control equipment.

2.The parts of the main equipment:electrolytic cell, auxiliary equipment integration framework. 

3.The parts of the auxiliary equipment:feed water tank,lye tank,feed water pump and the hydrogen frame for reducing pressure and distribution.

4.The parts of the electric control equipment: rectifier panel, control panel, distribution cabinet.

5.Features: The plant is designed specifically for power plant. Electrolyzer, gas-liquid treatment and hydrogen drying equipment are installed in a unit,so that occupying a smaller space. The product has high hydrogen purity and low humidity. It has a high level automation, and the plant could be started and shut down automatically by pressing the button.


Overall Dimension Of Drying Integration Hydrogen Generating Plants For Power Plant

The plant consists of one block hydrogen generating plant,the frame for hydrogen reducing pressure and distributing,control Panel,rectifier,transformer,feed water pump,feed water tank, Lye tank, analysis instruments.

I pneumatic combined instruments control;II electric instruments control;III PLC control;

IV FCS (Field Bus Control System).




technical parameter

The Plant integrated With Water Electrolvsis Hydrogen Generating and Drying For Power Plant

model

Component Name

length(mm)

width(mm)

height(mm)

DQ-5/3.2

frame I Frame I

3000

2000

2150

frame II Frame II

1740

1100

270(thick)

frame III Frame III

1500

1100

1500

DQ-10/3.2

frame I Frame I

3000

2000

2450

frame II Frame II

1800

1700

270(thick)

frame III Frame III

1740

1100

1360

 


Main technical indicators of integrated hydrogen production and drying device for power plants

model

Hydrogen production m³/h

Oxygen production m³/h

Operating pressure MPa

Hydrogen purity %

Hydrogen dew point ℃

DC power consumption

Tank overhaul cycle (year)

control mode


Kw-h/m³H2

DQ-5/3.2

5

2.5

3.2

≥99.8

≤-50

≤4.9

5月10日

I II III IV

DQ-10/3.2

10

5

3.2

≥99.8

≤-50

≤4.9

5月10日

I II III IV



文艺清新心灵鸡汤书籍封面 (3)